Verification of Calculation for the Protection of the Medical Cabin for Ion Therapy of Channel 26A of the Luch U-70 Project

https://doi.org/10.25205/2541-9447-2024-19-3-38-47

Abstract

Currently, the experience in designing installations using extracted carbon ion beams in Russia (the world) is very limited. The medical cabin for ion therapy of channel 26A of the LUCH U-70 project provides a unique opportunity for assessing the effectiveness of biological protection and verifying calculations. The paper presents data from experimental measurements of neutron radiation behind the biological protection of a medical cabin. The data were obtained for two energies of the extracted beam of accelerated carbon nuclei - 400 and 450 MeV/nucleon. The result is compared with the calculation performed using the FLUKA program for a given protection configuration. Good agreement between experimental data and calculations is shown.

About the Authors

V. A. Pikalov
Institute for High Energy Physics named after A. A. Logunov of National Research Center “Kurchatov Institute”
Russian Federation

Vladimir A. Pikalov, Head of laboratory

Protvino



O. V. Sumaneev
Institute for High Energy Physics named after A. A. Logunov of National Research Center “Kurchatov Institute”
Russian Federation

Oleg V. Sumaneev, Researcher

Protvino



M. M. Sukharev
Institute for High Energy Physics named after A. A. Logunov of National Research Center “Kurchatov Institute”
Russian Federation

Mikhail M. Sukharev, Lead Engineer

Protvino



References

1. Ahdida C. et al. New Capabilities of the FLUKA Multi-Purpose Code. Frontiers in Physics, 2022, vol. 9, pp. 788253.

2. Battistoni G. et al. Overview of the FLUKA code. Annals of Nuclear Energy, 2015, vol. 82, pp. 10-18.

3. Pikalov V. A., Antipov Y. M., Maximov A. V. et al. The results obtained on “Radiobiological stand” facility, working with the extracted carbon ion beam of the U-70 accelerator, CERN-Pro-ceedings: 27, 27th Russian Particle Accelerator Conference, RuPAC 2021, Alushta, 27 сентября - 01 октября 2021 года. Alushta, 2021, pp. 124-126. DOI:10.18429/JACoW-RuPAC2021-FRB06. - EDN MLAFQY.

4. Dosimeters-radiometers DKS-96 User manual SPC DOZA ТЕ1.415313.003РЭ. ОКП 43 6250 Version_7_14.02.2012 (in Russ.)

5. Sumaneev O. V., Azhgirey I. L., Baishev I. S., Pikalov V. A. Neutron field Measurements by GFPC based monitors at the Carbon beam at IHEP U-70 proton synchrotron. In: Proceedings of 27th Russian Particle Acc. Conf. RuPAC2021, Alushta, Russia, 2021, p. 129. DOI:10.18429/JACoW-RuPAC2021-FRC01